GREASE B GONE
Organica Grease B Gone is a "Patent Pending Dual Action Grease Treatment" Specifically developed To Address grease, oil, fat, and odor problems in municipal/industrial sewer lines, lift stations, scum pits, grease traps and other collection systems. This Bio formulation is composed of aerobic and facultative micro-organisms selected from nature for their adaptability and the ability to produce high levels of enzymes (lipases, amylases, proteases, cellulases) to facilitate the bio-degradation of the various organic substances found in collection systems and grease traps.
This formulation also contains a unique "Fast Oxygen Release System", which drastically increases dissolved oxygen levels within the system. By flooding the system with oxygen it drastically reduces anaerobic microbial populations and the odors typically associated with anaerobic conditions. The proprietary microbial species in this formulation are oxygen resistant and have the ability to withstand highly aerobic conditions.
DOSING FOR LIFT STATIONS & FORCE MAINS
FOR FACILITIES WITH DAILY FLOW LESS THAN 100,000 GALLONS
| Time of Treatment |
Number of Tablets |
Per Daily Flow of… |
| 1st 2 days |
9 |
10,000 gallons |
| Next 5 days |
3 |
10,000 gallons |
| Thereafter |
3 |
10,000 gallons |
Place product into waste-stream one or two manholes upstream from area to be treated
FOR FACILITIES WITH DAILY FLOW GREATER THAN 100,000 GALLONS
| Time of Treatment |
Number of Tablets |
Per Daily Flow of… |
| 1st 2 days |
9 |
10,000 gallons |
| Next 5 days |
6 |
10,000 gallons |
| Thereafter |
6 |
10,000 gallons |
Place product into waste-stream one or two manholes upstream from area to be treated
DOSING FOR GRAVITY MAINS AND FEEDER LINES
DAILY DOSE FOR CLEANUP PHASE
| Diameter of Line |
Number of Tablets |
| 4 inches |
3 |
| 6 inches |
3 |
| 8 inches |
6 |
| 10 inches |
12 |
| 12 inches |
15 |
| 14 inches |
18 |
| 16 inches |
24 |
| 18 inches |
30 |
| 20 inches |
36 |
| 22 inches |
48 |
| 24 inches |
54 |
Treat @ above rate for 4 days per 500 foot section. After treating furthest downstream 500 foot section for 4 days, repeat process for the next 500 feet upstream and continue process upstream until line is clean
WEEKLY DOSE FOR MAINTENANCE PHASE
| Diameter of Line |
Number of Tablets |
| 4 inches |
3 |
| 6 inches |
3 |
| 8 inches |
6 |
| 10 inches |
9 |
| 12 inches |
9 |
| 14 inches |
12 |
| 16 inches |
12 |
| 18 inches |
15 |
| 20 inches |
18 |
| 22 inches |
24 |
| 24 inches |
27 |
Above amounts are per 1,000 feet of line .For best results place product into waste-stream one or two manholes upstream from area to be treated
Dosing For Grease Traps
Clean out trap thoroughly and then begin program. For the first three days add 1 tablet per 150 gallons / 570 liters of tank capacity. Thereafter apply 1 tablet per 150 gallons / 570 liters of tank capacity per week. If tank is not cleaned prior to beginning program add 3 tablets per 150 gallons / 570 liters of tank capacity each day for 1 week. Thereafter apply 1 tablet per 150 gallons / 570 liters of tank capacity per week.
|